KDRY41LC7

Line Reactor (575V, 1440 Amps, 1500 HP, 3 Phase)
Representative image shown

$5,723.11
$12,735.00
Product Condition: New

TCI, KDR Series, 575V, 1440A, 1500HP, 3 Phase, NEMA 1, Input Line Inductor, Low Impedance, UL Recognized

SKU:
KDRY41LC7
Weight:
625.00 LBS
Width:
28.50 in
Height:
36.00 in
Depth:
30.30 in
Series:
KDR
Voltage:
575V
Amperage:
1440 Amps
Horsepower:
1500 HP
Number of Phases:
Three-phase

KDR line reactors are electrical components that help to protect 6-pulse rectifiers and power conversion devices such as variable frequency drives (VFDs). When used in conjunction with a VFD, a KDR line reactor can help reduce harmonics and protect the drive from harmful voltage spikes. KDR line reactors are recommended on the input of each VFD in multiple drive applications.

KDR reactors are constructed with durability in mind and can be used on both the input and output of a VFD. When used on the output of a drive, KDR reactors reduce voltage distortion at the motor terminals extending the service life and minimizing insulation stress of any motor.

Variable frequency drives (VFD) are beneficial to a wide range of applications, but contain a power conversion process that creates current and voltage distortion, known as harmonics.

Issues caused by harmonics may include:

  • Transformer and distribution equipment overheating
  • Random breaker tripping
  • Sensitive equipment failure
  • Poor power factor

NEMA Rating

  • N1
    Indoor
    Protection from fingers, tools and small objects
  • N12
    Indoor
    Protection from dust and light splashes of water
  • N3R
    Outdoor
    Protection from rain, snow and sleet
  • N4
    Outdoor
    Protection from rain, snow, sleet, and hose directed water
  • N4X
    Outdoor
    Protected from rain, snow, sleet, and pressure rated hose directed water from all angles

Advantages

  • Extend the life of the motor on the output of the VFD
  • Protect other equipment on the line from operational issues caused by voltage distortion
  • Dramatically increase drive uptime by reducing the likelihood of the drive tripping
  • Improve power factor
  • Reduce motor heating and audible noise
  • Increase system productivity

Benefits

  • Helps to meet IEEE 519-2014 requirements
  • 208 V-690 V; 0.25HP-1250HP
  • Available in Ultra Low, Low and High Impedance
  • Strong durable design specifically for VFD applications

Applications

  • HVAC Chillers & Systems
  • Pumps
  • Conveyors
  • Sprinkler Irrigation Systems
  • Pulp & Paper
  • Machining
  • Wastewater Treatment Plants
  • Oil & Gas
  • Irrigation Fields & Farms
  • Extruders
  • Steel Industry

Specifications

Amps 1500 Amps
Country of Origin US
DIN Rail Option None
Enclosure Type NEMA 1
Hertz 50/60 Hz
Horsepower 1500 HP
Impedance % 3%
Impedance Value 3% Low Z
Phase 3 Phase
Rated Voltage 575V
UL UL Recognized
Watts Loss 1791.0
Height 36.0 in
Width 28.5 in
Depth 30.3 in
Weight 625.0 lbs

Related Products